Fungal fragments in moldy houses: a field study in homes in New Orleans and southern Ohio
Abstract
Smaller-sized fungal fragments (<1 μm) may contribute to mold-related health effects. Previous laboratory-based studies have shown that the number concentration of fungal fragments can be up to 500 times higher than that of fungal spores, but this has not yet been confirmed in a field study due to lack of suitable methodology. We have recently developed a field-compatible method for the sampling and analysis of airborne fungal fragments. The new methodology was utilized for characterizing fungal fragment exposures in mold-contaminated homes selected in New Orleans, Louisiana and Southern Ohio. Airborne fungal particles were separated into three distinct size fractions: (i) >2.25 μm (spores); (ii) 1.05-2.25 μm (mixture); and (iii) < 1.0 μm (submicrometer-sized fragments). Samples were collected in five homes in summer and winter and analyzed for (1→3)-β-D-glucan. The total (1→3)-β-D-glucan varied from 0.2 to 16.0 ng m(-3). The ratio of (1→3)-β-D-glucan mass in fragment size fraction to that in spore size fraction (F/S) varied from 0.011 to 2.163. The mass ratio was higher in winter (average = 1.017) than in summer (0.227) coinciding with a lower relative humidity in the winter. Assuming a mass-based F/S-ratio=1 and the spore size = 3 μm, the corresponding number-based F/S-ratio (fragment number/spore number) would be 10(3) and 10(6), for the fragment sizes of 0.3 and 0.03 μm, respectively. These results indicate that the actual (field) contribution of fungal fragments to the overall exposure may be very high, even much greater than that estimated in our earlier laboratory-based studies.
Part of Mold & water-damaged buildings research · Curated by Lauren Lowenstein, The Biotoxin Lady
Key Biomarkers
Cited By (16)
- A water-damaged home and health of occupants: a case studyJournal of Environmental and Public Health · 2012
- Indoor Exposure to Mould AllergensArchives of Industrial Hygiene and Toxicology · 2002
- Fungal Contamination of Building Materials and the Aerosolization of Particles and Toxins in Indoor Air and Their Associated Risks to Health: A ReviewToxins · 2023
- Can we use indoor fungi as bioindicators of indoor air quality? Historical perspectives and open questionsThe Science of The Total Environment · 2010
- Exposure assessment of residential mould, fungi and microbial components in relation to children’s health: Achievements and challengesInternational Journal of Hygiene and Environmental Health · 2013
- Species of Fungi and Pollen in the PM1 and the Inhalable Fraction of Indoor Air in HomesAtmosphere · 2021
- Outdoor airborne allergens: Characterization, behavior and monitoring in EuropeThe Science of The Total Environment · 2023
- Dectin-1 and inflammation-associated gene transcription and expression in mouse lungs by a toxic (1,3)-β-d glucanArchives of Toxicology · 2009
- Direct-Read Fluorescence-Based Measurements of Bioaerosol Exposure in Home HealthcareInternational Journal of Environmental Research and Public Health · 2022
- Characterization of Indoor Molds after Ajka Red Mud Spill, HungaryPathogens · 2023
- Human health impactsFundamentals of Bioaerosols Science · 2023
- Mold and Human Health: a Reality Check.Clinical reviews in allergy & immunology · 2017
- Cultivation and aerosolization of Stachybotrys chartarum for modeling pulmonary inhalation exposure.Inhalation toxicology · 2019
- Chronic Illness Associated with Mold and Mycotoxins: Is Naso-Sinus Fungal Biofilm the Culprit?Toxins · 2014
- Detection of Mycotoxins in Patients with Chronic Fatigue SyndromeToxins · 2013
- Indoor mould exposure, asthma and rhinitis: findings from systematic reviews and recent longitudinal studiesEuropean Respiratory Review · 2018
References (8)
- Fungal Fragments as Indoor Air BiocontaminantsApplied and Environmental Microbiology · 2002
- Detection of AirborneStachybotrys chartarumMacrocyclic Trichothecene Mycotoxins on Particulates Smaller than ConidiaApplied and Environmental Microbiology · 2005
- Characterization of Airborne Molds, Endotoxins, and Glucans in Homes in New Orleans after Hurricanes Katrina and RitaApplied and Environmental Microbiology · 2007
- Aerodynamic characteristics and respiratory deposition of fungal fragmentsAtmospheric Environment · 2005
- Detection of AirborneStachybotrys chartarumMacrocyclic Trichothecene Mycotoxins in the Indoor EnvironmentApplied and Environmental Microbiology · 2005
- Mold and endotoxin levels in the aftermath of Hurricane Katrina: a pilot project of homes in New Orleans undergoing renovationEnvironmental Health Perspectives · 2006
- Airways inflammation and glucan in a rowhouse areaAmerican Journal of Respiratory and Critical Care Medicine · 1998
- Release of Streptomyces albus propagules from contaminated surfacesEnvironmental Research · 2003
Related Papers
- Dectin-1 and inflammation-associated gene transcription and expression in mouse lungs by a toxic (1,3)-β-d glucanArchives of Toxicology · 2009 · 5 shared tags
- Stachybotrys chartarum: cause of human disease or media darling?Medical Mycology · 2003 · 5 shared tags
- Airways inflammation and glucan in a rowhouse areaAmerican Journal of Respiratory and Critical Care Medicine · 1998 · 5 shared tags
- Characterization of Airborne Molds, Endotoxins, and Glucans in Homes in New Orleans after Hurricanes Katrina and RitaApplied and Environmental Microbiology · 2007 · 5 shared tags
- Stachybotrys chartarum, Trichothecene Mycotoxins, and Damp Building–Related Illness: New Insights into a Public Health EnigmaToxicological Sciences · 2008 · 5 shared tags
- The biocontaminants and complexity of damp indoor spaces: more than what meets the eyesToxicology and Industrial Health · 2009 · 5 shared tags