← Explorer/Network

Respiratory inflammatory responses among occupants of a water-damaged office building

Akpinar-Elci M, Siegel PD, Cox-Ganser JM +4 more2008Indoor AirJournal Article
10.1111/j.1600-0668.2007.00514.xPubMed
Immune/InnateRespiratory/Sinus
Indoor Mold (Stachybotrys, Aspergillus, etc.)Water-Damaged Buildings (WDB)

Abstract

UNLABELLED: The National Institute for Occupational Safety and Health (NIOSH) received a request for evaluation of a water-damaged office building which housed approximately 1300 employees. Workers reported respiratory conditions that they perceived to be building related. We hypothesized that these symptoms were associated with airways inflammation. To test this hypothesis, we assessed airways inflammation in employees using exhaled breath condensate (EBC) and the fraction of exhaled nitric oxide (FENO). In September 2001, a health questionnaire was offered to all employees. Based on this questionnaire, NIOSH invited 356 symptomatic and asymptomatic employees to participate in a medical survey. In June 2002, these employees were offered questionnaire, spirometry, methacholine challenge test, allergen skin prick testing, EBC and FENO. FENO or EBC were completed by 239 participants. As smoking is highly related to the measurements that we used in this study, we included only the 207 current non-smokers in the analyses. EBC interleukin-8 (IL-8) levels, but not nitrite, were significantly higher among workers with respiratory symptoms and in the physician-diagnosed asthmatic group. Of the analyses assessed, EBC IL-8 showed the most significant relationship with a number of symptoms and physician-diagnosed asthma. PRACTICAL IMPLICATIONS: Implementation of exhaled breath condensate and exhaled nitric oxide in indoor air quality problems.

Key Biomarkers

FENOIL-8Nitrite

Symptom Clusters

AsthmaRespiratory symptoms

Cited By (2)

  • Impact of Epidemic Intelligence Service Training in Occupational Respiratory EpidemiologyATS Scholar · 2023
  • Markers of upper airway inflammation associated with microbial exposure and symptoms in occupants of a water‐damaged buildingAmerican Journal of Industrial Medicine · 2013

References (4)

  • Respiratory Morbidity in Office Workers in a Water-Damaged BuildingEnvironmental Health Perspectives · 2005
  • Induced Production of Nitric Oxide, Tumor Necrosis Factor, and Interleukin-6 in RAW 264.7 Macrophages by Streptomycetes from Indoor Air of Moldy HousesArchives of Environmental Health An International Journal · 1997
  • Inflammatory responses in Raw264.7 macrophages caused by mycobacteria isolated from moldy housesEnvironmental Toxicology and Pharmacology · 2000
  • Adverse health effects among adults exposed to home dampness and moldsAmerican Review of Respiratory Disease · 1991

Related Papers

  • Mold inhalation causes innate immune activation, neural, cognitive and emotional dysfunctionBrain Behavior and Immunity · 2020 · 4 shared tags
  • THIRTY YEARS OF PUBLISHED RESEARCH ON HUMAN HEALTH EFFECTS OF EXPOSURE TO THE INTERIOR ENVIRONMENT OF WATER-DAMAGED BUILT ENVIRONMENTSMedical Research Archives · 2025 · 4 shared tags
  • Dampness and moulds in workplace buildings: Associations with incidence and remission of sick building syndrome (SBS) and biomarkers of inflammation in a 10 year follow-up studyThe Science of The Total Environment · 2012 · 4 shared tags
  • Poorly controlled asthma – Easy wins and future prospects for addressing fungal allergyAllergology International · 2023 · 4 shared tags
  • Effects of Mycotoxins on Neuropsychiatric Symptoms and Immune ProcessesClinical Therapeutics · 2018 · 4 shared tags
  • The Myth of Mycotoxins and Mold InjuryClinical Reviews in Allergy & Immunology · 2019 ·
4 shared tags