Analysis of pulmonary surfactant by fourier-transform infrared spectroscopy following exposure to Stachybotrys chartarum (atra) spores
Abstract
Lung cells are among the first tissues of the body to be exposed to air-borne environmental contaminants. Consequently the function of these cells may be altered before other cells are affected. As gas exchange takes place in the lungs, changes in cellular function may have serious implications for the processes of oxygen uptake and carbon dioxide elimination. In order for these processes to occur, the lung must maintain a high degree of expandability. This latter function is accomplished in part by the pulmonary surfactant which is synthesized and released by alveolar type II cells. Earlier studies have shown that exposure to gas phase materials such as smoke or organic solvents can alter the composition and function of the surfactant. The present study examines the ability of highly toxigenic mold spores to alter surfactant composition. Stachybotrys chartarum spores suspended in saline were instilled into mouse trachea as described earlier. After 24 h, the lungs were lavaged and the different processing stages of surfactant isolated by repeated centrifugation. Intracellular surfactant was isolated from the homogenized lung tissue by centrifugation on a discontinuous sucrose gradient. Samples were extracted into chloroform-methanol, dried and analyzed by Fourier-Transform infrared spectroscopy (FTIR). Exposure to S. chartarum induced an overall reduction of phospholipid among the three surfactant subfractions. The intermediate and spent surfactant fractions in particular were reduced to about half of the values observed in the saline-treated group. The relative distribution of phospholipid was also altered by spore exposure. Within the intracellular surfactant pool, higher levels of phospholipid were detected after spore exposure. In addition, changes were observed in the nature of the phospholipids. In particular strong intramolecular hydrogen bonding, together with other changes, suggested that spore exposure was associated with absence of an acyl chain esterified on the glycerol backbone, resulting in elevated levels of lysophospholipid in the samples. This study shows that mold spores and their products induce changes in regulation of both secretion and synthesis of surfactant, as well as alterations in the pattern of phospholipid targeting to the pulmonary surfactant pools.
Cited By (7)
- Localization of Satratoxin-G in Stachybotrys chartarum Spores and Spore-Impacted Mouse Lung Using ImmunocytochemistryToxicologic Pathology · 2004
- Microanatomical Changes in Alveolar Type II Cells in Juvenile Mice Intratracheally Exposed to Stachybotrys chartarum Spores and ToxinToxicological Sciences · 2002
- Stachybotrys chartarum: cause of human disease or media darling?Medical Mycology · 2003
- Histological, immunohistochemical and morphometric changes in lung tissue in juvenile mice experimentally exposed to Stachybotrys chartarum sporesMycopathologia · 2002
- Stachybotrys chartarum, Trichothecene Mycotoxins, and Damp Building–Related Illness: New Insights into a Public Health EnigmaToxicological Sciences · 2008
- Indoor Mold, Toxigenic Fungi, andStachybotrys chartarum: Infectious Disease PerspectiveClinical Microbiology Reviews · 2003
- Comparison of inflammatory and cytotoxic lung responses in mice after intratracheal exposure to spores of two different Stachybotrys chartarum strains
Related Papers
- Misalignment between Clinical Mold Antigen Extracts and Airborne Molds Found in Water-damaged HomesAnnals of the American Thoracic Society · 2021 · 2 shared tags
- Microbiological Analysis of Indoor Air in Selected Primary Schools: Health Concerns and RecommendationsJournal of Multidisciplinary Science MIKAILALSYS · 2023 · 2 shared tags
- Dampness, mould, onset and remission of adult respiratory symptoms, asthma and rhinitisEuropean Respiratory Journal · 2019 · 2 shared tags
- Microbial Air Quality in the Built Environment—Case Study of Darvas-La Roche Heritage Museum House, Oradea, RomaniaBuildings · 2023 · 2 shared tags
- Assessment of Mould Risk in Low-Cost Residential Buildings in Urban Slum Districts of Surakarta City, IndonesiaBuildings · 2023 · 2 shared tags
- Impact of positive pressure ventilation systems on indoor air quality in residential settingsBuilding and Environment · 2025 ·