← Explorer/Network

Association Between Air Microbiological Exposure With Sick Building Syndrome (SBS) among College Dormitory Students in Public University

Nurul Nadia Abdul Rahim, Juliana Jalaludin, Ernie Syazween Junaidi +1 more2023Malaysian Journal of Medicine and Health SciencesJournal Article
10.47836/mjmhs.19.s14.5Free full text
DermatologicalRespiratory/Sinus
Indoor Mold (Stachybotrys, Aspergillus, etc.)Water-Damaged Buildings (WDB)

Abstract

Introduction: Microbiological pollutants in indoor air can lead to sick building syndrome (SBS). A conducive academic environment in university dormitories requires healthy indoor air quality to enhance student performance. This study aimed to determine the association between indoor air microbiological exposure and SBS among college dormitory students at a public university. Methods: A cross-sectional study was conducted among 112 male and female college dormitory students who stayed in the public university dormitory for more than three months. Respondents were given a self-administered questionnaire-based NIOSH Indoor Environmental Quality Survey. 14 houses were selected for the measurement of indoor air quality which included PM2.5, PM10, relative humidity (%), temperature (°C), air velocity (m/s), indoor bacterial concentration (cfu/m3), and indoor mould concentration (cfu/m3). Results: Higher percentages of SBS symptoms were reported among female (94.6%) college dormitory students compared to male (82.1%). A significant difference in itching symptom on the arms and forearms was found among individuals of different genders (p<0.05). Indoor air parameters such as temperature (OR = 2.56, 95% CI = 2.66-9.87), relative humidity (OR = 1.77, 95% CI = 1.54 – 5.79), indoor bacteria concentration (OR=2.28, 95% CI = 2.48 – 10.93), and indoor mould concentration (OR=2.59, 95% CI = 1.75 – 8.98) were significantly associated with the recent SBS symptoms. Multiple logistic regression showed that the most significant predictor of SBS was indoor mould concentration. Conclusion: Exposure to high concentrations of indoor bacteria and mould, high temperatures, and high relative humidity influenced the prevalence of SBS among college dormitory students. Further assessment and preventive action need to be taken to reduce the exposure of indoor air microbiological to the students.

Cited By (1)

  • The study of effective factors in sick building syndrome related to fungi and its control methodsResults in Engineering · 2024

References (2)

  • Biological contaminants in the indoor air environment and their impacts on human healthAir Quality Atmosphere & Health · 2021
  • Association between indoor microbiome exposure and sick building syndrome (SBS) in junior high schools of Johor Bahru, MalaysiaThe Science of The Total Environment · 2021

Related Papers

  • Dampness and moulds in workplace buildings: Associations with incidence and remission of sick building syndrome (SBS) and biomarkers of inflammation in a 10 year follow-up studyThe Science of The Total Environment · 2012 · 4 shared tags
  • Poorly controlled asthma – Easy wins and future prospects for addressing fungal allergyAllergology International · 2023 · 4 shared tags
  • Literature Analysis on Stachybotrys chartarum and Connections to Sick Building SyndromeWestern Undergraduate Research Journal Health and Natural Sciences · 2023 · 4 shared tags
  • Association of exposure to indoor molds and dampness with allergic diseases at water-damaged dwellings in KoreaScientific Reports · 2024 · 4 shared tags
  • A Review of the Role of Indoor Fungi in Sick Building SyndromeInternational Journal of Medical Laboratory · 2023 · 4 shared tags
  • A Large Case-series of Successful Treatment of Patients Exposed to Mold and MycotoxinClinical Therapeutics · 2018 ·
4 shared tags