Effect of ultraviolet germicidal lights installed in office ventilation systems on worker’s health and wellbeing: double-blind multiple crossover trial
Abstract
BACKGROUND: Workers in modern office buildings frequently have unexplained work-related symptoms or combinations of symptoms. We assessed whether ultraviolet germicidal irradiation (UVGI) of drip pans and cooling coils within ventilation systems of office buildings would reduce microbial contamination, and thus occupants' work-related symptoms. METHODS: We undertook a double blind, multiple crossover trial of 771 participants. In office buildings in Montreal, Canada, UVGI was alternately off for 12 weeks, then turned on for 4 weeks. We did this three times with UVGI on and three times with it off, for 48 consecutive weeks. Primary outcomes of self-reported work-related symptoms, and secondary outcomes of endotoxin and viable microbial concentrations in air and on surfaces, and other environmental covariates were measured six times. FINDINGS: Operation of UVGI resulted in 99% (95% CI 67-100) reduction of microbial and endotoxin concentrations on irradiated surfaces within the ventilation systems. 771 participants appeared to remain masked, and reported no adverse effects. On the basis of within-person estimates, use of UVGI was associated with significantly fewer work-related symptoms overall (adjusted odds ratio 0.8 [95% CI 0.7-0.99]), as well as respiratory (0.6 [0.4-0.9]) and mucosal (0.7 [0.6-0.9]) symptoms than was non-use. Reduction of work-related mucosal symptoms was greatest among atopic workers (0.6 [0.5-0.8]), and never-smokers (0.7 [0.5-0.9]). With UVGI on, never-smokers also had large reduction of work-related respiratory (0.4 [0.2-0.9]), and musculoskeletal symptoms (0.5 [0.3-0.9]). INTERPRETATION: Installation of UGVI in most North American offices could resolve work-related symptoms in about 4 million employees, caused by microbial contamination of heating, ventilation, and air-conditioning systems. The cost of UVGI installation could in the long run prove cost-effective compared with the yearly losses from absence because of building-related illness.
Cited By (3)
- Public health and economic impact of dampness and moldIndoor Air · 2007
- Indoor air quality level influence sick building syndrome among occupants in educational buildingsInternational Journal of Public Health Science (IJPHS) · 2022
- Control of airborne infectious disease in buildings: Evidence and research prioritiesIndoor Air · 2021
Related Papers
- Synergistic interaction in simultaneous exposure to Streptomyces californicus and Stachybotrys chartarumEnvironmental Health Perspectives · 2004 · 5 shared tags
- Comparison of inflammatory and cytotoxic lung responses in mice after intratracheal exposure to spores of two different Stachybotrys chartarum strainsToxicological Sciences · 2004 · 5 shared tags
- Localization of Satratoxin-G in Stachybotrys chartarum Spores and Spore-Impacted Mouse Lung Using ImmunocytochemistryToxicologic Pathology · 2004 · 5 shared tags
- Correction to “Maitotoxin induces biphasic interleukin-1β secretion and membrane blebbing in murine macrophages”Mol Pharmacol · 2004 · 5 shared tags
- HUMAN VISUAL FUNCTION IN THE NORTH CAROLINA CLINICAL STUDYON POSSIBLE ESTUARY-ASSOCIATED SYNDROMEJournal of Toxicology and Environmental Health · 2001 · 5 shared tags
- Effectiveness of cholestyramine in the detoxification of zearalenone as determined in miceBulletin of Environmental Contamination and Toxicology · 1995 ·