A comparison of several media types and basic techniques used to assess outdoor airborne fungi in Melbourne, Australia.
Abstract
Despite the recent increase in interest in indoor air quality regarding mould, there is no universally accepted standard media for the detection of airborne fungi, nor verification of many commonly used techniques. Commonly used media including malt-extract agar (MEA), Sabouraud dextrose agar (Sab), potato dextrose agar (PDA) with and without antibiotics chloramphenicol & gentamycin (CG) were compared for their suitability in detecting a range of airborne fungi by collecting 150 L outdoor air on a number of different days and seasons via an Anderson 400-hole sampler in suburban Melbourne, Australia. There was relatively little variation in mean numbers of colony forming units (CFU) and types of fungi recovered between MEA, PDA, Sab media groups relative to variation within each group. There was a significant difference between Sab, Dichloran-18% glycerol (DG18) and V8® Original juice agar media, however. Antibiotics reliably prevented the growth of bacteria that typically interfered with the growth and appearance of fungal colonies. There was no significant evidence for a growth enhancing factor from potato, mineral supplements or various vegetable juices. Differing glucose concentrations had modest effects, showing a vague ideal at 2%-4% with peptone. Sanitisation of the aluminium Andersen 400-hole sampler top-plate by flame is possible, but not strictly required nor advisable. The use of SabCG as a standard medium was generally supported.
Part of Mold & water-damaged buildings research · Curated by Lauren Lowenstein, The Biotoxin Lady
References (3)
- Environmental factors influencing fungal growth on gypsum boards and their structural biodeterioration: A university campus case study.PloS one · 2019
- Associations between Fungal Species and Water-Damaged Building MaterialsApplied and Environmental Microbiology · 2011
- A different suite: The assemblage of distinct fungal communities in water-damaged units of a poorly-maintained public housing building.PloS one · 2019
Related Papers
- Misalignment between Clinical Mold Antigen Extracts and Airborne Molds Found in Water-damaged HomesAnnals of the American Thoracic Society · 2021 · 1 shared tag
- Microbiological Analysis of Indoor Air in Selected Primary Schools: Health Concerns and RecommendationsJournal of Multidisciplinary Science MIKAILALSYS · 2023 · 1 shared tag
- Fungal immunity and pathogenesis in mammals versus the invertebrate model organismGalleria mellonellaPathogens and Disease · 2021 · 1 shared tag
- Association of mold exposure and solid household fuel use with depression and anxiety among older adults in ChinaEnvironmental Health · 2025 · 1 shared tag
- Dampness, mould, onset and remission of adult respiratory symptoms, asthma and rhinitisEuropean Respiratory Journal · 2019 · 1 shared tag
- Self-reported mould and long-term sickness absences from work.Scandinavian journal of public health · 2021 · 1 shared tag