Work-related peak flow and asthma symptoms in a damp building
Abstract
BACKGROUND: Working in damp conditions is associated with asthma, but few studies have used objective testing to document work-related patterns. AIMS: To describe the relationship of peak flow measurements to work-related asthma (WRA) symptoms and WRA among occupants in a damp office building. METHODS: At the beginning of the study, all workers were offered a questionnaire and methacholine challenge testing. Participants were then instructed to perform serial spirometry using handheld spirometers five times per day over a 3 week period. Peak flow data were analysed using OASYS-2 software. We calculated the area between the curves (ABC score) using hours from waking. We considered a score >5.6 L/min/h to be indicative of a work-related pattern. RESULTS: All 24 employees participated in the questionnaire. Seven participants (29%) reported physician-diagnosed asthma with onset after starting work in the building. Almost two-thirds (63%) of participants reported at least one lower respiratory symptom (LRS) occurring one or more times per week in the last 4 weeks. Twenty-two (92%) consented to participate in serial spirometry. Fourteen participants had adequate quality of serial spirometry, five of whom had ABC scores >5.6, ranging from 5.9-23.0. Of these five, two had airways responsiveness, three had current post-hire onset physician-diagnosed asthma and four reported work-related LRS. CONCLUSIONS: We found evidence of work-related changes in serial peak flows among some occupants of an office building with a history of dampness. Serial peak flows may be a useful measure to determine WRA in office settings.
Symptom Clusters
Related Papers
- Misalignment between Clinical Mold Antigen Extracts and Airborne Molds Found in Water-damaged HomesAnnals of the American Thoracic Society · 2021 · 2 shared tags
- Dampness, mould, onset and remission of adult respiratory symptoms, asthma and rhinitisEuropean Respiratory Journal · 2019 · 2 shared tags
- Microbial Air Quality in the Built Environment—Case Study of Darvas-La Roche Heritage Museum House, Oradea, RomaniaBuildings · 2023 · 2 shared tags
- A Transcriptomic Fingerprint for Parkinson's Disease Found in Patients with Chronic Inflammatory Response Syndrome: Implications for Diagnosis, Treatment and PreventionMedical Research Archives · 2024 · 2 shared tags
- Mold inhalation causes innate immune activation, neural, cognitive and emotional dysfunctionBrain Behavior and Immunity · 2020 · 2 shared tags
- Going over Fungal Allergy: Alternaria alternata and Its AllergensJournal of Fungi · 2023 ·