← Explorer/Network

Impact of domestic mould exposure on Aspergillus biomarkers and lung function in patients with chronic obstructive pulmonary disease

Émilie Fréalle, Gabriel Reboux, Olivier Le Rouzic +8 more2021Environmental ResearchJournal Article
10.1016/j.envres.2021.110850PubMedFree full text
Respiratory/Sinus
Indoor Mold (Stachybotrys, Aspergillus, etc.)

Abstract

Patients with chronic obstructive pulmonary disease (COPD) are frequently colonised or sensitised by Aspergillus, but clinical significance remains unclear. Furthermore, little is known on the impact of indoor mould exposure during COPD. In this study, we assessed the relationship between domestic mould exposure, Aspergillus biomarkers and COPD severity during acute exacerbation and at stable state. Aspergillus section Fumigati culture in sputum and anti-Aspergillus antibodies detection (IgG and precipitins) were followed up in COPD patients that were prospectively recruited during exacerbation (n = 62), and underwent a visit at stable state after 18 months (n = 33). Clinical characteristics were collected at inclusion. Electrostatic dust collectors (EDCs) were used to measure domestic mould contamination. Aspergillus section Fumigati was more frequently detected during exacerbation (16.9%) than at stable state (4.0%), but the frequency of patients presenting with anti-Aspergillus antibodies was similar (32.2% and 33.3%, respectively). Aspergillus section Fumigati detection was associated with a higher body-mass index (BMI) during exacerbation, whereas patients with anti-Aspergillus antibodies presented a lower BMI and forced expiratory volume in 1 s, as well as a higher frequency of inhaled corticoids and higher total mould and Penicillium exposure at final visit (P < 0.05). The frequency of patients with anti-Aspergillus antibodies was higher for total mould counts >30 CFU/cm

Cited By (2)

  • Medizinisch klinische Diagnostik bei Schimmelpilzexposition in Innenräumen – Update 2023 (AWMF-Register-Nr. 161/001)Pneumologie · 2024
  • AWMF mold guideline “Medical clinical diagnostics for indoor mold exposure” – Update 2023 AWMF Register No. 161/001Allergologie select · 2024

References (2)

  • Correlation between the prevalence of certain fungi and sick building syndromeOccupational and Environmental Medicine · 1998
  • Indoor mould exposure, asthma and rhinitis: findings from systematic reviews and recent longitudinal studiesEuropean Respiratory Review · 2018

Related Papers

  • Misalignment between Clinical Mold Antigen Extracts and Airborne Molds Found in Water-damaged HomesAnnals of the American Thoracic Society · 2021 · 2 shared tags
  • Microbiological Analysis of Indoor Air in Selected Primary Schools: Health Concerns and RecommendationsJournal of Multidisciplinary Science MIKAILALSYS · 2023 · 2 shared tags
  • Dampness, mould, onset and remission of adult respiratory symptoms, asthma and rhinitisEuropean Respiratory Journal · 2019 · 2 shared tags
  • Microbial Air Quality in the Built Environment—Case Study of Darvas-La Roche Heritage Museum House, Oradea, RomaniaBuildings · 2023 · 2 shared tags
  • Assessment of Mould Risk in Low-Cost Residential Buildings in Urban Slum Districts of Surakarta City, IndonesiaBuildings · 2023 · 2 shared tags
  • Impact of positive pressure ventilation systems on indoor air quality in residential settingsBuilding and Environment · 2025 ·
2 shared tags